The Rotor Control Board for Portable X-Ray by GE Healthcare is essential for the AMX 4 and AMX 700 systems. It efficiently manages power distribution to critical components, ensuring reliable operation and safety in diagnostic imaging. Its lightweight design enhances portability, making it ideal for various clinical environments. The Rotor Control Board is used in the AMX4 plus and the AMX 700 systems. It consists of primarily the 60Hz inverter which supplies 60Hz of power to the collimator field lamp, X ray tube stator, X ray tube filament and HV inverter module stop capacitor. the sense X ray tube stator runs and starts winding current. This board can activate and deactivate the safety contactor. The control board consists of a resistor, capacitor, transformer, IC chips, connector slot and cooling unit. A 60Hz 24V square wave’s inverter with a controlled dead band are applied to opto isolators. The opto, in turn drives a push pull driver stage consisting of Q60/Q73 and Q61/Q74 and then it feeds to the ZMOD1 and/or ZMOD2 which consist of MOSFET transistors that are responsible for energizing the output transformer in push pull mode. The output transformer feeds back to the rotor band which distributes the output to a specific subsystem and generates diagnostic outputs used by the controller board. Additional Features: Lightweight Handle with care and safety
This Rotor Control Board is compatible with the following models:
It is typically used in portable X-ray applications, particularly in emergency settings, outpatient clinics, and patient transport scenarios where mobility and rapid imaging capabilities are essential.
| Parameter | Value |
|---|---|
| Power Supply Frequency | 60 Hz |
| Output Voltage | 24 V |
| Weight | Lightweight |
| Components | Resistor, Capacitor, Transformer, IC Chips |
| Cooling Mechanism | Integrated Cooling Unit |
The Rotor Control Board enhances procurement strategies by providing a reliable and efficient solution for portable X-ray systems. Its compatibility with multiple GE Healthcare models allows for streamlined inventory management and reduces the need for multiple parts across different devices. This versatility ensures that healthcare facilities can maintain operational efficiency while minimizing downtime during equipment maintenance.
In terms of maintenance, the robust design of the Rotor Control Board, which includes essential electronic components and safety features, contributes to reduced service interruptions. The lightweight nature of the board facilitates easier handling and installation, allowing biomedical engineers to perform routine checks and replacements swiftly. This not only enhances workflow but also ensures that imaging services remain uninterrupted, ultimately supporting better patient outcomes.
The Rotor Control Board is used in the AMX4-plus and the AMX 700 systems. It consists of primarily the 60Hz inverter which supplies 60Hz of power to the collimator field lamp, X-ray tube stator, X-ray tube filament and HV inverter module stop capacitor. the sense X-ray tube stator runs and starts winding current. This board can activate and deactivate the safety contactor. The control board consists of a resistor, capacitor, transformer, IC chips, connector slot and cooling unit. A 60Hz 24V square wave’s inverter with a controlled dead band are applied to opto isolators. The opto, in turn drives a push-pull driver stage consisting of Q60/Q73 and Q61/Q74 and then it feeds to the ZMOD1 and/or ZMOD2 which consist of MOSFET transistors that are responsible for energizing the output transformer in push-pull mode. The output transformer feeds back to the rotor band which distributes the output to a specific subsystem and generates diagnostic outputs used by the controller board. Additional Features: Lightweight Handle with care and safety
Models
AMX 4, DEFINIUM AMX 700, AMX 700